速報APP / 生產應用 / EWP 2014 Electrical Wiring Pro

EWP 2014 Electrical Wiring Pro

價格:免費

更新日期:2016-12-05

檔案大小:3.8M

目前版本:1.1

版本需求:Android 2.2 以上版本

官方網站:http://www.intineo.com

Email:support@intineo.com

聯絡地址:164 Doud Drive Los Altos, CA 94022

EWP 2014 Electrical Wiring Pro(圖1)-速報App

Updated from Electrical Wiring Pro (2011) to include the 2014 NEC.

New features per 2014 NEC include:

- Residential Service/Feeder calculation using the 83% method rather than

the old Table 310(B)(7)

- Revised Electrical Nonmetallic Tubing sizing per the larger values in the

new code

- 1000 Volts replaces 600 Volts for select calculations

Over 40 Useful Electrical Calculators & Tools, each of which could be an app

in its own right.

For Electricians, Power Engineers and other Electrical Professionals.

Written by a working Electrician using it on a daily basis.

Calculations per National Electrical Code 2014, 2011, 2008 or 2005.

o Residential/Load Calculations

EWP 2014 Electrical Wiring Pro(圖2)-速報App

- Single Family Dwelling

- Multi Family Dwelling

- Range Calculations

- Send results via email for verification and documentation

o Ampacity / Wire Size (AWG only)

- Wire Size -> Ampacity

- Ampacity Needed -> Wire Size

- Voltage Drop -> Wire Size

- Dwelling Service Size

- GEC Size

- EGC Size

- New Ampacity section includes

o Improved user interface,

EWP 2014 Electrical Wiring Pro(圖3)-速報App

o NEC 2005, 2008 and 2011 (the updates are accounted for by the app)

o > 700 locations with Ambient Temps

o Boxes / Cover

- Box Size from Wires / Devices

- Box Size from Cables / Devices

- Standard Box and Typical Plaster Ring INfo

- Pull Box Sizing

o Conduit Fill

- Wires -> Conduit Size Needed

- Wires/Conduit -> % full

- Maximum Wires/Conduit

- Conduit Size Details

- Wire Size Details

EWP 2014 Electrical Wiring Pro(圖4)-速報App

o Conduit Bending

- Standard and Rolled Offsets

- Parallel Offsets

- 3-point Saddle

- Round and rectangular corner obstacles

- Segment Bends

- Minimum Bend Radius One-Shot/Full Shoe or Other bends

o Voltage Drop

- Required voltage or % drop -> Wire Size

- Voltage Drop Calculation

- Maximum Length for voltage or % drop

- Maximum Load for voltage or % drop

- Impedance given wire length

EWP 2014 Electrical Wiring Pro(圖5)-速報App

o Motors

- FLC, Wire, Breaker, Heater, Starter, Conduit etc. Sizing

- Locked Rotor Current

- KVAR Capacitor Correction

- NEMA Motor Dimensions

oTransformers

- Basic Transformer Sizing

- Overcurrent Protection Device Sizing

- Transformer Faults

- Delta-Wye configuration

o Wire / Device info

- Standard Receptacle configurations

- AWG-Metric wire size comparison

EWP 2014 Electrical Wiring Pro(圖6)-速報App

- Ethernet TIA-568A/B Color Codes

- RJ 11/14/25 Color Codes

- Resistor Color Codes

o Other

- In-Foot <-> Metric, Construction Fraction <-> Decimal converter

- Parallel Load Calculator

- Pire Wheel / Ohms Law

- Cover Depth

- Temperature Conversion for 8 different scales

New features will be added to EWP 2014. The previous Electrical Wiring Pro

(now EWP 2011) will go into maintenance mode for bug fixes only.

If you would like to report bugs or suggestions, please send them to:

support aatt intineo dot com

EWP 2014 Electrical Wiring Pro(圖7)-速報App

rather than use the comment mechanism so we can respond

directly -- thank you.

EWP 2014 Electrical Wiring Pro(圖8)-速報App